gasoline tanker fire response ©️Remtech Engineers

Division of SET Environmental


10,000 Environmental Remediations Since 1975

24 Hr Emergency Response

800-377-3648

Spill Prevention Systems & Secondary Containment at Railyards

Locations:  Alabama, Kentucky, Missouri, North Carolina, Ohio, South Carolina, Virginia, West Virginia

Client: Major Railroad

Contract Amount: $1,560,000+

Remtech Precast Stormwater Spill Prevention Weir Boxes

Remtech Precast Stormwater Spill Prevention Weir Boxes



SPILL PREVENTION PROBLEM AT MULTIPLE RAILYARDS


Remtech was authorized by a major railroad to construct secondary containment and spill prevention and control systems at railyards in eight states.


SECONDARY CONTAINMENT SPILL PREVENTION AT 8 RAILYARDS


Spill prevention and secondary containment facilities constructed and installed by Remtech consisted of:

➣ Earth/Rock Containment

➣ Contact Water Diversion Swales

➣ New Manholes & Connecting Piping

➣ Concrete Containment Dikes, Curbs & Headwalls

➣ Stormwater Containment Underflow Weirs

➣ Automated Sluice Gates

➣ Overhead Fuel Piping and Bridges

➣ Automated Fuel Control Valves

➣ Split Casing Secondary Containment Piping

➣ Leak Detection Valves

➣ Hydrocarbon Sensors

➣ Control Valves & Pumps

➣ Protective Bollards & Access Grates

➣ Bank Stabilization & Erosion Control

➣ Protective Coatings

SECONDARY CONTAINMENT SPILL PREVENTION AT 8 RAILYARDS COST/BENEFITS


50,000 lb reinforced precast concrete underflow weir boxes and bases were fabricated at Remtech's facility in Atlanta and shipped up to 600 miles. The pre-fabricated boxes were lowered into excavations inside trench boxes. Fabrication of precast structures was considerably less expensive than forming and installing onsite.